Skip to main content
Loading…
This paragraph is included in your selections.

A. Opacity

1. The buffer standards in the table below address the opacity of the buffer that is required on the property boundary between zoning districts, and in some instances within a zoning district.

2. An opacity of 0.1 screens 10%, and an opacity of 1.0 would fully screen the use from adjacent properties during summer months no more than five years after planting.

B. Project Boundary Buffer Table

ZONING DISTRICT OF ADJACENT PROPERTY

RR and PDR
in Rural Tier

RS-20, RS-10, RS-8 and
PDR in Suburban Tier

RU and PDR
in Urban Tier

RS-M, RU-M

RC

CI

CN

OI

SRP

SRP-C (County Only)

MU

UC

CG

CC

IL

IP

I

ZONING DISTRICT OF SUBJECT PROPERTY

RR and PDR in Rural Tier

0/

0

0/

.2

.2/

.6

.2/

.8

.2/

.8

0/

.2

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

.2/

.6

.2/

.6

.2/

.8

.2/

.8

.2/

.8

.2/

.8

.2/

1.0

RS-20, RS-10, RS-8 and PDR in Suburban Tier

.2/

.2

0/

0

.2/

.4

.2/

.6

.2/

.6

0/

.2

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

.2/

.6

.2/

.6

.2/

.8

.2/

.8

.2/

.8

.2/

.8

.2/

1.0

RU and PDR in Urban Tier

.4/

.6

.2/

.4

0/

0

.2/

.6

.2/

.6

0/

.2

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

.2/

.6

.2/

.6

.2/

.8

.2/

.8

.2/

.8

.2/

.8

.2/

1.0

RS-M, RU-M

.6/

.8

.4/

.6

.4/

.6

.2/

.4

.2/

.4

0/

.2

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

.2/

.6

.2/

.6

.2/

.8

.2/

.8

.2/

.8

.2/

.8

.2/

1.0

RC

.6/

.8

.4/

.6

.4/

.6

.2/

.4

0/

0

0/

.2

0/

0

.2/

.6

.2/

.6

.2/

1.0

.2/

.6

.2/

.6

.2/

.6

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

CI

.2/

.2

.2/

.2

.2/

.2

.2/

.2

.2/

.2

0/

0

0/

0

0/

0

0/

0

0/

0

0/

0

0/

0

0/

0

0/

0

.2/

.4

.2/

.4

.2/

.4

CN

.4/

.6

.4/

.6

.4/

.6

.4/

.6

0/

0

0/

0

0/

0

0/

0

0/

0

.2/

.6

0/

0

0/

0

.2/

.6

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

OI

.4/

.6

.4/

.6

.4/

.6

.4/

.6

.4/

.6

0/

0

0/

0

0/

0

0/

0

.2/

.6

0/

0

0/

0

.2/

.6

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

SRP

.4/

.6

.4/

.6

.4/

.6

.4/

.6

.4/

.6

0/

0

0/

0

0/

0

0/

0

0/

0

0/

0

0/

0

.2/

.6

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

SRP-C
(County Only)

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

0/

0

.4/

.6

.4/

.6

0/

0

0/

0

.4/

.6

.4/

.6

.2/

4

.2/

4

.2/

4

.2/

.4

.2/

1.0

MU

.4/

.6

.4/

.6

.4/

.6

.4/

.6

.4/

.6

0/

0

0/

0

0/

0

0/

0

.2/

.6

0/

0

0/

0

.2/

.6

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

UC

.4/

.6

.4/

.6

.4/

.6

.4/

.6

.4/

.6

0/

0

0/

0

0/

0

0/

0

.2/

.6

0/

0

0/

0

.2/

.6

.2/

.6

.2/

.6

.2/

.6

.2/

1.0

CG

.6/

.8

.6/

.8

.6/

.8

.6/

.8

.4/

.6

0/

0

.4/

.6

.4/

.6

.4/

.6

.2/

.4

.4/

.6

.4/

.6

.2/

.4

.2/

.4

.2/

.4

.2/

.4

.2/

1.0

CC

.6/

.8

.6/

.8

.6/

.8

.6/

.8

.4/

.6

0/

0

.4/

.6

.4/

.6

.4/

.6

.2/

.4

.4/

.6

.4/

.6

.2/

.4

.2/

.4

.2/

.4

.2/

.4

.2/

1.0

IL

.6/

.8

.6/

.8

.6/

.8

.6

.8

.4/

.6

.2/

.4

.4/

.6

.4/

.6

.4/

.6

.2/

.4

.4/

.6

.4/

.6

.2/

.4

.2/

.4

.2/

.4

.2/

.4

.2/

1.0

IP

.6/

.8

.6/

.8

.6/

.8

.6/

.8

.4/

.6

.2/

.4

.4/

.6

.4/

.6

.4/

.6

.2/

.4

.4/

.6

.4/

.6

.2/

.4

.2/

.4

.2/

.4

.2/

.4

.2/

1.0

I

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.2/

.4

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.8/

1.0

.2/

.4

How to Use this Table: The second number represents the Total Buffer, which normally occurs across the property line, with unequal responsibility for buffering on both sides of the line based on intensity of the use or district. Therefore:

1. The first number indicates the required opacity when adjacent to undeveloped land.

2. The second number is the opacity required when adjacent to a development without a buffer.

3. If a buffer exists on adjacent property, the required opacity on the property to be developed shall be the difference between the opacity on the adjacent property from the total, or second, opacity number.

4. A zero means no project boundary buffer is required.

Example: A new development in the CG District abutting a developed RS District without a buffer would be required to provide a buffer with a total opacity of .8 (80% opaque). If the adjacent RS property were undeveloped, the requirement would be reduced to .6 (60% opaque), and the developer of the RS property would provide the remaining .2 (20%) at the time of development of the residential property.

C. Modifications of the Project Boundary Buffer Table

1. Multiplex and apartment development proposed in any district to be adjacent to single-family or two-family developments on other properties shall provide buffers in accordance with the provisions for RS-M if in the Suburban tier or RU-M in the Urban tier.

2. Nonresidential development proposed in a residential district to be adjacent to residential districts or residential developments (except for upper story residential or with any intervening street or railroad right-of-way) on other properties, that would not otherwise require a buffer, shall provide buffers in accordance with the provisions of the CN District in determining buffer requirements. Principal uses listed in paragraph 5.2.4F, Parks and Open Areas, except playgrounds and zoos, are exempt from this requirement.

3. Nonresidential uses proposed next to property used for residential purposes, although nonresidentially zoned, shall provide a buffer along the side of the property adjoining the property used residentially equivalent to one-half of the buffer width that would have been required for property with a residential zoning designation within that Tier. Except for industrial uses, as an alternative to a buffer, a wall pursuant to paragraph 9.4.8, Walls, Berms and Fences in Buffers, may be provided.

4. The buffer requirement for a subject property zoned Industrial Light (IL) adjacent to property zoned Industrial (I), per the table in paragraph 9.4.3B, shall be 0.2/0.4 when the subject property is four acres or less in size.

5. Some uses may require additional buffering, as set forth in the specific use standards of Sec. 5.3, Limited Use Standards.

6. For residential development utilizing mass grading, a minimum opacity of 0.6 shall be required, unless a greater opacity is otherwise required.

7. Single-family and two-family subdivision in the RU-M District shall not require buffers adjacent to, or across right-of-way from, RU-5 or RU-5(2) Districts and single-family or two-family development in the RU-M District.

D. Major Specimen Trees Protected

Existing major specimen trees located within a required project boundary buffer shall be surveyed and protected as described in paragraphs 8.3.5 and 9.3.2, Existing Trees. Removal of such trees is allowed only as required to provide access to the property.

E. Any development that is adjacent to property located in another jurisdiction shall provide a minimum of 60% opaque buffer per the tier of the subject development site along the boundary that is adjacent to the other jurisdiction.